Question 1
Two calibrated voltmeters disagree at a dry-soil pipeline test point: the 10 megohm meter reads -0.640 V and the 100 megohm meter reads -0.900 V. They use the same structure lead and saturated copper/copper sulfate electrode, and both agree on a low-resistance voltage source. The reference electrode also passes a comparison check in moist soil. Rectifier output is stable. What is the most useful next field check?
Show answer & explanation
Correct answer: B - Improve the reference-electrode contact with the soil and repeat the potential measurements.